Endress Hauser FMP54 PFA Coated Probe Guided Radar Level Transmitter for High Pressure (400 bar) and Temperature Shock Resistant (-196 °C to +200 °C) Slurry Level Measurement

1
MOQ
US $850.00 - 1050.00/ Set
価格
Endress Hauser FMP54 PFA Coated Probe Guided Radar Level Transmitter for High Pressure (400 bar) and Temperature Shock Resistant (-196 °C to +200 °C) Slurry Level Measurement
特徴 ギャラリー 製品の説明 見積依頼
特徴
仕様
材料: ステンレス鋼
測定原則: 誘導レーダー
プロセス圧力/最大。過剰圧力制限: 真空...400 bar (真空...5800 psi)
コミュニケーション: 4 ... 20 Ma Hart Profibus PA Foundation Fieldbus
周囲温度: -50...+80 °C (-58...+176 °F)
センサーの長さ: ロッドプローブ:10m /ローププローブ:45m /同軸プローブ:6m
ハイライト:

PFA coated radar level transmitter

,

guided radar slurry level probe

,

E+H FMP54 level measurement

基本情報
ブランド名: Endress+Hauser
モデル番号: FMP54
お支払配送条件
パッケージの詳細: 必要に応じて
受渡し時間: 60日
支払条件: T/T
供給の能力: 年間1000セット
製品の説明
Product Overview

In ammonia storage spheres, LPG bullets and small LNG tanks the FMP54 with coaxial probe is installed everywhere. The coaxial version has no dead zones and measures right to the bottom even with very low dielectric (εr ≥ 1.4). It handles the big temperature swings from filling cold product to warm ambient without losing signal. Many plants have been running the same FMP54 for 15+ years with zero maintenance.

What Makes It Special for Low-Temperature Service
  • Coaxial probe – measures ammonia (εr ≈ 1.6) without problems
  • Temperature shock resistant – from -196 °C to +200 °C in minutes
  • No moving parts, no drift, no recalibration
  • Gas-tight ceramic coupling – safe for toxic NH3
  • Works in stilling wells and bypass pipes perfectly
Main Numbers
Media Liquid ammonia, LPG, LNG, N2, CO2, etc.
Temperature range -196 °C to +200 °C
Pressure range vacuum to 100 bar
Probe type Coaxial 42 mm (standard for ammonia)
Accuracy ±2 mm
Where You See Them Every Day
  • Ammonia storage spheres and tanks
  • LPG bullets and horton spheres
  • Small-scale LNG tanks
  • Refrigerant storage
Common Questions

Q: Will it work when the tank is cold and then warms up?
A: Yes – the ceramic coupling handles 400 K temperature shock without issues.

Q: Do I need a stilling well?
A: Not mandatory, but many customers use the coaxial probe inside existing stilling wells.

Contact Us

Email: edwardzhao@gbsxj.com

Phone/WhatsApp/WeChat: +8615000725058

Related Instruments
  • FMP51 coaxial for standard applications
  • FMR62 80 GHz radar for bigger tanks
  • Proservo NMS81 for custody transfer