logo

Liquids Water Gas Steam Flowmeter E+H 7D2C 7F2C 7R2C 7O2C Proline Prowirl D200 F200 R200 O200 Endress Hauser Vortex Flow Meter

1
MOQ
US $1500.00 - 2100.00/ Set
価格
Liquids Water Gas Steam Flowmeter E+H 7D2C 7F2C 7R2C 7O2C Proline Prowirl D200 F200 R200 O200 Endress Hauser Vortex Flow Meter
特徴 ギャラリー 製品の説明 見積依頼
特徴
仕様
マックス。プロセス圧力: PN100,クラス600,20K
生産量: 4-20mA HART (パッシブ)
デジタル通信: ハート,プロフィバス PA,ファウンデーションフィールドバス
最高。測定誤差: 音量流量 (標準): ±0.5% o.r. ±1 mm/s (0.04 イン/s)
電源: DC12~35V
中程度の温度範囲: 標準: -40~+260℃ (-40~+500°F)
基本情報
ブランド名: Endress+Hauser
モデル番号: プロワールF200
お支払配送条件
パッケージの詳細: ご要望通り
受渡し時間: 60日
支払条件: T/T
供給の能力: 年間1000セット
製品の説明

Endress+Hauser Prowirl F 200 Vortex Flowmeter

The one vortex meter that doesn’t lie when steam gets wet

Why People Buy Prowirl F 200 Instead of Cheaper Vortex Meters

Every other vortex meter on the market starts reading high or just gives up when steam quality drops below 95%. The Prowirl F 200 doesn’t care – it still reads correctly even at 100% wetness (pure water). It uses a special two-wire capacitive sensor that looks at the whole flow profile, not just one bluff body edge. Result: you get real mass flow of steam no matter how wet it is. Power plants, refineries and chemical plants have been using it for years and finally stopped arguing about “who is stealing my steam".

Things That Actually Matter on Site

  • Wet steam compensation built-in – no extra pressure/temperature sensors needed
  • Same sensor measures steam, gases, liquids – no range changes
  • ±0.75% accuracy for liquids, ±1% for steam/gas – real numbers, not marketing
  • Dual compartment housing + separate terminal box – easy wiring in the rain
  • Heartbeat Technology – push one button, get a signed verification report
  • Works down to Reynolds 4000 – no long straight runs needed

Quick Specs

Sizes DN15 – DN300 (½" – 12")
Pressure rating up to PN100 / Class 600 (higher on request)
Temperature -200 °C to +400 °C
Media Steam (even 100% wet), gases, liquids
Output 4–20 mA HART, Pulse, Status + mass/energy with built-in T/P compensation
Approvals ATEX, IECEx, FM, CSA, SIL 2/3
Display Big backlit LCD – can read it from the ladder

Where You See Them Every Day

  • Power plant main steam lines (wet steam after turbines)
  • Refinery saturated steam headers
  • Chemical plant process steam (often wet)
  • Compressed air billing between plants
  • Natural gas and biogas custody transfer

Questions We Get on Every Job

Q: Will it really measure 100% wet steam?
A: Yes – the capacitive sensor sees the whole flow, not just vortices.

Q: Do I need external pressure and temperature?
A: No – built-in compensation version F 200 has P and T sensors inside.

Q: How do I prove it’s still accurate?
A: Press the Heartbeat button – 30 seconds later you have a signed PDF report.

Contact Us

Email: edwardzhao@gbsxj.com

Phone/WhatsApp/WeChat: +8615000725058

Other Stuff From the Same Family

  • Prowirl D 200 – low-cost version for liquids only
  • Prowirl O 200 – high-pressure gas version
  • Promass F 200 – Coriolis if you need ultimate accuracy