logo

Fisher 67CFR Filter Regulator Flowserve Logix 3410MD-28-D6-M-04-50-0G-00 Digital Valve Controller Positioner

1
MOQ
2500 dollars
価格
Fisher 67CFR Filter Regulator Flowserve Logix 3410MD-28-D6-M-04-50-0G-00 Digital Valve Controller Positioner
特徴 ギャラリー 製品の説明 評価とレビュー 見積依頼
特徴
仕様
コミュニケーション: FOUNDATION フィールドバス (ITK 5.1)
入力信号: バスパワー、9 ~ 32 V DC
アクチュエータの種類: 単動・複動、リニア・ロータリー
ストローク範囲: 3~130mm(直線)/30~100°(回転)
空気供給: 30 ~ 150 psig (2 ~ 10 バール)
空気消費量: <0.3 SCFM (0.5 Nm3/h) @ 60 psi
囲い: 粉体塗装アルミニウム (IP65)
動作温度: -40 ~ +85 °C (-40 ~ +185 °F)
基本情報
起源の場所: 中国
ブランド名: Flowserve
モデル番号: 3410MD-28-D6-M-04-50-0G-00
ドキュメント: LGENIM3404_EN_LTR.pdf
お支払配送条件
パッケージの詳細: カートン +木製の木枠 +保護パッケージ
受渡し時間: 70 日
支払条件: T/T
供給の能力: 年間700台
製品の説明
Product Overview

The Flowserve Logix 3410MD-28-D6-M-04-50-0G-00 is an intelligent FOUNDATION Fieldbus digital positioner optimized for single-acting actuators. With full FF interoperability, advanced predictive diagnostics, and low steady-state air consumption, it provides real-time valve health monitoring and seamless integration into digital automation systems.

Key Features
  • Full Fieldbus Functionality: Supports AO, PID, DI/DO, OS, IS blocks plus manufacturer-specific diagnostics.
  • Predictive Maintenance: Valve signature, step response, multi-step response, and performance tests.
  • Local User Interface: 3-button operation with LED status and local jog control.
  • Advanced Alerts: 3-stage alarm hierarchy (green/yellow/red) for friction, travel, and deviation.
  • FISCO Compliant: Intrinsically safe for hazardous areas with low power requirements.
  • Link Master Capable: Can act as backup LAS in the fieldbus segment.
Technical Specifications
Parameter Details
Protocol FOUNDATION Fieldbus (Link Master)
Power Supply Bus-powered 9–32 V DC
Current Consumption 18 mA typical
Function Blocks AO, PID, DI (2), DO, OS, IS
Enclosure Aluminum
Diagnostics Valve Signature, PST, Cycle Counter, Travel Accumulator
Ambient Temperature -52 to +80 °C (T4) / -52 to +60 °C (T6)
Supply Air 1.4–10.3 bar, clean dry instrument air
Applications
  • Safety Instrumented Systems (SIS) with partial stroke testing
  • Refineries and petrochemical plants with Fieldbus infrastructure
  • Power plants requiring continuous valve health monitoring
  • Any FF-based control loop needing predictive maintenance data
Frequently Asked Questions
  • What is included in the valve signature? Friction, spring characteristics, hysteresis, and breakout pressures recorded during operation.
  • How often should I run a Partial Stroke Test? Automatically scheduled or on-demand; ideal for safety valves without full stroke interruption.
  • Does it require a separate power supply? No – fully bus-powered from the Fieldbus segment.
  • Can I view diagnostics remotely? Yes – via any FF host, 375 communicator, or ValveSight software.
  • Is this model Link Master capable? Yes – it can serve as backup Link Active Scheduler.
Contact Us

Phone/WeChat/WhatsApp:

+8613916209596

Email: svetama@gbsxj.com

Related Products
  • Flowserve Logix 3400MD with HART
  • Flowserve ValveSight PRM diagnostic platform
  • Flowserve Logix 3200IQ+ analog positioner
  • Flowserve StarPac 3 intelligent control valve
  • National Instruments NI-FBUS Configurator
評価とレビュー

総合評価

5.0
このサプライヤーに対する50件のレビューに基づいています

ランキングスナップショット

すべての評価の分布は以下の通りです
5 星
100%
4 星
0%
3 星
0%
2 星
0%
1 星
0%

すべてのレビュー

A
Alex
Switzerland Dec 1.2025
great price and fast delivery
推薦されたプロダクト
私達と連絡を取ってください
コンタクトパーソン : Mr. Edward Zhao
電話番号 : +8615000725058
残りの文字数(20/3000)