logo

Industrial Safety DET-TRONICS PointWatch Eclipse PIRECL Infrared Gas Detector Hydrocarbon Combustible Gas Detector

1
MOQ
US $3000.00 - 6800.00/ Unit
価格
Industrial Safety DET-TRONICS PointWatch Eclipse PIRECL Infrared Gas Detector Hydrocarbon Combustible Gas Detector
特徴 ギャラリー 製品の説明 評価とレビュー 見積依頼
特徴
仕様
対象ガス: 炭化水素ガス
コミュニケーション: ハート / RS-485
供給電圧: 24 VDC (18 ~ 32 VDC 動作範囲)
点型赤外線拡散センサー: 316 ステンレス鋼 (CF8M 鋳造)
動作温度: -40°C〜 +75°C
寸法: 約236*132*117mm
重さ: 約4.8kg
侵入保護: IP66 / IP67
出力信号: アナログ出力4〜20mA
応答時間: ≤ 1.5 秒 (通常)
基本情報
起源の場所: アメリカ合衆国
ブランド名: DET-TRONICS PointWatch Eclipse
モデル番号: ピレク
お支払配送条件
パッケージの詳細: 段ボール箱・木箱
受渡し時間: 8~12週
支払条件: T/T
供給の能力: 年間500ユニット
製品の説明
DET-TRONICS PointWatch Eclipse PIRECL Infrared Hydrocarbon Gas Detector
Product Overview

PointWatch Eclipse PIRECL is an open-path infrared hydrocarbon gas detector that uses infrared absorption technology to detect flammable gases in the air. It measures the gas concentration over a line-of-sight path (typically 5–60 meters). The detector is designed for hazardous areas and is widely used where fast, reliable detection of methane, propane, ethylene and other hydrocarbons is required without false alarms from poisons or contaminants.

Features
  • Open-path detection – covers large area with single unit
  • Immune to most poisons and contaminants
  • Heated optics – prevents condensation and fogging
  • Automatic optical integrity (oi) test – continuous self-check
  • FM, CSA, ATEX, IECEx approvals for hazardous locations
  • HART communication for diagnostics and setup
  • Optional relay and analog output
Technical Specifications
  • Detection Range: 0–5 LFL-m (methane equivalent)
  • Path Length: 5 m to 60 m (16 ft to 200 ft) typical
  • Response Time: T90 ≤ 3 seconds
  • Spectral Region: 3.3 μm hydrocarbon absorption band
  • Operating Temperature: –55 °C to +75 °C (–67 °F to +167 °F)
  • Supply Voltage: 18–32 Vdc
  • Power Consumption: 11.5 W nominal, 23 W max (heated)
  • Output: 4–20 mA (HART), optional relays
  • Enclosure: Stainless steel or aluminum
  • Approvals: FM, CSA, ATEX, IECEx, SIL 2 capable
Applications
  • Offshore platforms and FPSOs
  • Refineries and petrochemical plants
  • Compressor stations
  • LNG terminals
  • Open-area flammable gas detection
FAQ

Q: How does it avoid false alarms?

A: Infrared technology ignores most poisons, steam, and contaminants.

Q: Path length?

A: Up to 60 meters typical.

Related Products
  • PointWatch Eclipse PIRDUCT (ducted version)
  • PointWatch Eclipse PIRECL with relay option
  • FlexSonic acoustic leak detector
  • CGS500 catalytic sensor
評価とレビュー

総合評価

5.0
このサプライヤーに対する50件のレビューに基づいています

ランキングスナップショット

すべての評価の分布は以下の通りです
5 星
100%
4 星
0%
3 星
0%
2 星
0%
1 星
0%

すべてのレビュー

A
Alex
Switzerland Dec 1.2025
great price and fast delivery
推薦されたプロダクト
私達と連絡を取ってください
コンタクトパーソン : Mr. Edward Zhao
電話番号 : +8615000725058
残りの文字数(20/3000)